Flyline Modular Digital Over & Under Voltage Protector

09447366779, 09400464444

红包扫雷表情图搞笑fdp modular digital over & under voltage protector is self –healing phase failure and phase sequence for 3 phase protective relay and it’s a brand new germen technology equipment invented by murickens group to protect household electrical devices .when we apply flyline digital protector- it can quickly disconnect the power supply to protect the appliances when there is power interruption or the voltage exceeds of falls below the predetermined value.when the power supply recovers, flyline protector automatically connects the power after 1-2 minutes delay.all the protective actions are automatically controlled and indications on its panel display show the working condition of the fdp.this fdp is maintaining indian national quality standards, most excellent in performance and releability. it is very compact and convenient to use


►Rated Power Supply : AC220V 50Hz Operating Voltage: 100-400 V (avoid burning out of electrical appliances under 380 voltage)►Passing Max. Current : 32A,63A. ►Max. Loading Power in Single Phase :7KVA,14KVA ►Over-voltage Action Cut-off Value : AC260±5V, action 0.01second action delay. Recovered Value : AC260±5V. (230-270V adjustable ►Under-voltage Cut-off Value : AC180±5V,0.1 seconds’ action delay. Recovered Value : AC195±5V.(120-210V adjustable).►Time Delay: Start time for First Connection: 15 Second. Delay time is free to set from 5 to 600 seconds after the first time.►Rapid action: The power disconnects the appliances with in 1 sec.►Self Power Consumption : ≤ 3W.►Dimensions (MM) : 84x52x75(LxWxH)

TECHNICAL SPECIFICATION OF Single Phase Flyline Modular Digital Over & Under Voltage Protector :

Model FDP-1
Number of Poled 1 P
Rated Voltage (V)AC 220
Rated Current (A) 32         |          63
Loading Power (KVA) 7 KVA         |          14 KVA
Over-Voltage Cut-Off Value(VAC) 230-270         adjustable ( 400 V short time)
Time Delay(s) 0.01 seconds
Under-Voltage Cut-Off Value(VAC) 120-210         adjustable
Time Delay(s) 0.1 seconds
Dimensions(MM) 84*52*75(L*W*H)
Self Power Consumption(W) ≤ 3w
Ambient Temperature (C ) -20-+40

instruction for use:1 Phase

1.This button : for displaying the voltage (3 phase or 1 phase )Press the button for 10s to switch to single phase voltage indicating.
2. The second button : :delay time setting.Press the button for 10s until the decimal point flashes.Then press button "+"or "-" to set the delay time(5-600s)
3. The third button under voltage value setting. Press the button for 10s then the decimal point of digital panel flashes. Then press “ + ” or “ - ”to set the voltage (120-210V)
4. The fifth button 红包扫雷表情图搞笑: over voltage value setting. Press the button for 10s, then the decimal point on digital panel will flash. The press “ + ” or “ – ”to set the voltage ( 230-270V)

The Protector will act if the following occurs

红包扫雷表情图搞笑►sequence disorder.►phase unbalance.►breakage of neutral line.►breakage of any live line.►over-voltage of any phase.►under-voltage of any phase.

TECHNICAL SPECIFICATION OF Three Phase Flyline Modular Digital Over & Under Voltage Protector :

Model FDP-3
Number of Poled 3 P
Rated Voltage (V)AC 220
Rated Current (A) 32         |          63
Loading Power (KVA) 20 KVA         |          40 KVA
Over-Voltage Cut-Off Value(VAC) 230-270         adjustable
Time Delay(s) 0.01 seconds
Under-Voltage Cut-Off Value(VAC) 120-210         adjustable
Time Delay(s) 0.1 seconds
Dimensions(MM) 85*90*75(L*W*H)
Self Power Consumption(W) ≤ 3W
Ambient Temperature (C ) -20-+40

conditions of use

►relative humidity:≤85%.►latitude:≤2000m.►no corrosive gas or conductive dust.►instalation :vertical mounting on din rail

Precautions:line of neutral of this product does not have function of isolating.Please cut offm isolating switch before operation

instruction for use:3 Phase

1.This button : for displaying the voltage (3 phase or 1 phase )Press the button for 10s to switch to single phase voltage indicating.
2. The second button : :delay time setting.Press the button for 10s until the decimal point flashes.Then press button "+"or "-" to set the delay time(5-600s)
3. The third button under voltage value setting. Press the button for 10s then the decimal point of digital panel flashes. Then press “ + ” or “ - ”to set the voltage (120-210V)
4. The fifth button : over voltage value setting. Press the button for 10s, then the decimal point on digital panel will flash. The press “ + ” or “ – ”to set the voltage ( 230-270V)

press the forth button ,the last time fault voltage will be displayed in 2 seconds .the lights indicate the fault phase

Fault Indication

1.Wire Connection Error
Flashing letters CBA on the board indicates phase sequence error .Change connecting sequence of the live lines to solve this problem.(if OPO appears first and then CBA flashes.Please check if the neutral line and live line where reversely connected.)
2.Phase Loss
OPO :Lack of neutral line.►:OPA : Lack of Phase A live line.►:OPB Lack of Phase B live line.►:OPC Lack of Phase C live line
The display board is not lighted:lack of 2 or 3 phases of live lines

3.Phase Imbalance:H-L appears when voltage difference between any two phases is over 35%(>77V)

红包扫雷表情图搞笑 4.over or under voltage protection :h and l on the left ,center and rigt of the indicating board stand for over voltage and under voltage of phase a ,b and c respectively.




Flyline Modular Digital Guard Application Image :-Click Here

green energy promotion videos by mg group:-

红包扫雷表情图搞笑watts of some electronic products we use :-

flyline solar power plant installation video of mg marketing system:-  

红包扫雷表情图搞笑 murickens govt clients list :-  

murickes brouchure:-

for quick response & order-call ( 91) 09400464444,  09447366779, 08281848484

app微信红包扫雷平台 红包扫雷小程序都是骗人的 红包扫雷群截图50 红包扫雷群号 玩微信红包扫雷软件